Forge
Continuis Labs · Sensor Forge

The open registry for field-deployed sensors & probes

Forge is a community-curated library of sensor and probe definitions — the authoritative source of truth for every device that connects to Vigil. Each definition carries parametric specs, communication protocols, EEPROM descriptors, and physical-quantity mappings that let Argus understand exactly what your sensors are measuring, at what range and resolution. Definitions power automatic unit conversion, anomaly context, and natural-language diagnostics across your whole fleet.

Star definitions your deployments depend on
Fork & customise for proprietary hardware variants
Flash EEPROM descriptors directly to probes via PDP
307
Definitions
Submit Sensor
1–17 of 17 sensors matching "afe"
Schrader Electronics · 33500
Mechanical ✓ Official

Direct TPMS valve-stem sensor transmitting tire pressure and temperature at 315/433 MHz RF. 0–120 psi range, 0.25 psi r…

RF 315/433 MHz
tpmstire-pressurerfschraderfleet +2 more
Texas Instruments · AFE4400
Other ✓ Official

Integrated analog front end for SpO2 pulse oximetry with LED driver, transimpedance amplifier, and ADC. SPI interface, …

SPI
spo2pulse-oximeterafetispi +3 more
Other ✓ Official

8-channel simultaneous 24-bit biopotential amplifier with 1 µV RMS noise for clinical EEG and EMG. SPI interface, integ…

SPI
eegemgbiopotentialafeti +4 more
Texas Instruments · ADS1293
Other ✓ Official

24-bit 3-channel simultaneous ECG analog front end with 0.4 µV noise floor and 1.8 V supply. SPI interface, integrated …

SPI
ecgbiopotentialafetispi +3 more
Mechanical ✓ Official

Vibrating wire piezometer for pore water pressure monitoring in dams, embankments, and foundations. 350/700 kPa range, …

RS-232 / Modbus
vibrating-wirepiezometerpore-pressuregeokondam +1 more
Sensing Labs · ULP12
Optical ✓ Official

Surface UV-C fluence sensor for 254 nm disinfection dose measurement in hospital and food safety applications. 0–20 mJ/…

Analog
uv-cdisinfection-doseanaloghospitalfood-safety +1 more
PBI (Pharmaceutical Business Intelligence) · CheckPoint
Environmental ✓ Official

Multi-channel temperature and humidity cold chain monitor with RS-232/Modbus output. −40–85°C temperature range, 0–100%…

RS-232 / Modbus
cold-chaintemperaturehumidityrs232pbi +2 more
Environmental ✓ Official

Compact USB temperature data logger for cold chain transport monitoring. −35–70°C range, ±0.5°C accuracy, 400-day batte…

USB
cold-chaintemperature-loggerusbtestotransport +2 more
Sensitech · TempTale 4
Environmental ✓ Official

Bluetooth LE cold chain temperature data logger for pharmaceutical and food transport monitoring. −30–60°C range, ±0.5°…

Bluetooth LE
cold-chaintemperature-loggerbluetoothsensitechpharma +1 more
Heidenhain · EQN 1325
Position / Motion ✓ Official

Absolute multiturn rotary encoder with EnDat 2.2 serial interface. 4096 turns × 8192 positions per turn, functional saf…

EnDat 2.2 / SSI
encoderabsolutemultiturnendatsil2 +1 more
SICK · AFS60A-BDAK065536
Position / Motion ✓ Official

Safety-capable absolute encoder with SSI, EtherCAT, Profibus, and CANopen variants. 30-bit resolution, SIL 2 functional…

SSI / EtherCAT / Profibus
encoderabsolutessisil2sick +2 more
Mechanical ✓ Official

Modbus RTU linear polarisation resistance (LPR) corrosion rate transmitter. Electrochemical technique for real-time pit…

Modbus RTU
corrosionlprmodbusrs-485atex +1 more
MSA Safety · XCell Pulse
Chemical ✓ Official

Smart catalytic bead (pellistor) combustible gas sensor transmitter with 4–20 mA and Modbus RTU outputs. 0–100% LEL det…

4–20 mA / Modbus RTU
analyticalcombustiblecatalyticrs485chemical +5 more
Honeywell Analytics (City Technology) · 4CF2
Chemical ✓ Official

3-electrode electrochemical CO sensor for safety monitoring applications. 0–500 ppm CO range, ±3% FS accuracy, 300–600 …

Analog (µA current)
coanalyticalchemicalgaswater-quality +2 more
Chemical ✓ Official

3-electrode electrochemical carbon monoxide sensor. 0–1000 ppm CO range, < 2% FS accuracy, sensitivity 350–550 nA/ppm. …

Analog (µA current)
coanalyticalchemicalgaswater-quality +2 more
Chemical ✓ Official

4-electrode amperometric electrochemical sensor for carbon monoxide detection. 0–1000 ppm CO range, ±2% FS accuracy. Au…

Analog (µA current)
coanalyticalchemicalgaswater-quality +2 more
Figaro Engineering · TGS2611-E00
Chemical ✓ Official

Tin-oxide MOX resistive gas sensor for methane (CH₄) and LPG detection. 500–10000 ppm CH₄ range. Resistance decreases w…

Analog (resistance)
moxanalyticalchemicalgaswater-quality +2 more
Argus
Operational insights · Institutional memory
Argus is thinking…