The open registry for field-deployed sensors & probes
Forge is a community-curated library of sensor and probe definitions — the authoritative source of truth for every device that connects to Vigil. Each definition carries parametric specs, communication protocols, EEPROM descriptors, and physical-quantity mappings that let Argus understand exactly what your sensors are measuring, at what range and resolution. Definitions power automatic unit conversion, anomaly context, and natural-language diagnostics across your whole fleet.
Guided wave radar (GWR) level transmitter using TDR technology. HART 5 and 4–20 mA output, suitable for solids, liquids…
80 GHz free-radiating radar level sensor for liquids, 0–30 m range, ±2 mm accuracy. HART 7 and 4–20 mA output, SIL 2 ca…
Deep-sea optical dissolved oxygen optode, 0–500 µmol/L, depth-rated to 6000 m. Luminescent lifetime measurement princip…
Luminescent dissolved oxygen sensor for sc200 controller, 0–20 mg/L, <0.1 mg/L error. No membrane changes, no electroly…
Solar-aspirated radiation shield housing Pt100 temperature and capacitive RH sensors with 4–20 mA outputs. Forced venti…
Two-wire Coriolis mass flowmeter with ±0.1% mass flow accuracy. HART output, hygienic process connections available. Me…
High-accuracy Coriolis mass flowmeter with ±0.05% mass flow accuracy. Simultaneously measures mass flow, volume flow, d…
DN20 inline vortex flowmeter for 1–100 L/min water measurement. 4–20 mA and NPN pulse outputs, ±2% accuracy, IP67. Push…
Calorimetric flow sensor for water and aqueous media, 0–2.5 L/min. IO-Link and 4–20 mA outputs, integrated temperature …
Stainless steel turbine flowmeter covering 0.12–1500 L/min. Dual output: 4–20 mA analogue and pulse/frequency. Suitable…
Dual-frequency excitation magnetic flowmeter with ±0.2% accuracy. HART output, TIIS and ATEX certified. Dual-ADMAG tech…
Multi-electrode magnetic flowmeter for conductive liquids. DN10–2400, ±0.2% accuracy, 4–20 mA / HART. Multi-electrode d…
Vortex flowmeter for steam, liquids, and gases. DN15–300, ±0.75% accuracy, 4–20 mA / HART. Integrated temperature and p…
Custody-transfer ultrasonic gas flowmeter for natural gas and process gas applications. Multipath design, SIL 2 capable…
Non-invasive clamp-on transit-time ultrasonic flowmeter for DN15–4000 pipes. ±1.5% accuracy, RS-232 and 4–20 mA outputs…
Electromagnetic flowmeter optimised for wastewater and utility water. DN50–300, ±0.5% accuracy, HART output, IP67/68. P…
Electromagnetic flowmeter for conductive liquids (≥5 µS/cm). DN10–3000 range, ±0.5% accuracy, 4–20 mA / HART / Modbus R…
Smart catalytic bead (pellistor) combustible gas sensor transmitter with 4–20 mA and Modbus RTU outputs. 0–100% LEL det…
Amplified, compensated flush-diaphragm strain gauge transducer with 4–20 mA output. Intended for both liquid/gas pressu…
Dual-axis inclinometer with 4–20 mA and RS-232 outputs. ±10° range, 0.001° resolution. Force-balance electrolytic sensi…
Two-wire 4–20 mA vibration transmitter with user-configurable frequency band and full-scale range. Measures velocity RM…
Dual-channel 4–20 mA transmitter outputting vibration RMS on channel 1 and temperature on channel 2. Accepts IEPE accel…
Industrial vibration and temperature transmitter with dual 4–20 mA outputs. First channel: broadband vibration RMS (10–…
Loop-powered 4–20 mA vibration transmitter combining an internal IEPE accelerometer with RMS signal processing. Output …
