Forge
Continuis Labs · Sensor Forge

The open registry for field-deployed sensors & probes

Forge is a community-curated library of sensor and probe definitions — the authoritative source of truth for every device that connects to Vigil. Each definition carries parametric specs, communication protocols, EEPROM descriptors, and physical-quantity mappings that let Argus understand exactly what your sensors are measuring, at what range and resolution. Definitions power automatic unit conversion, anomaly context, and natural-language diagnostics across your whole fleet.

Star definitions your deployments depend on
Fork & customise for proprietary hardware variants
Flash EEPROM descriptors directly to probes via PDP
307
Definitions
Submit Sensor
1–24 of 32 sensors matching "4-20ma"  · Page 1 of 2
Environmental ✓ Official

Guided wave radar (GWR) level transmitter using TDR technology. HART 5 and 4–20 mA output, suitable for solids, liquids…

HART 5 / 4–20 mA
guided-wave-radarlevelharttdr4-20ma
Environmental ✓ Official

80 GHz free-radiating radar level sensor for liquids, 0–30 m range, ±2 mm accuracy. HART 7 and 4–20 mA output, SIL 2 ca…

HART 7 / 4–20 mA
radarlevelhart80ghz4-20ma +1 more
Aanderaa Data Instruments · 4835
Chemical ✓ Official

Deep-sea optical dissolved oxygen optode, 0–500 µmol/L, depth-rated to 6000 m. Luminescent lifetime measurement princip…

RS-232 / 4–20 mA
deep-seaanalyticalopticalchemicaldissolved-oxygen +2 more
Chemical ✓ Official

Luminescent dissolved oxygen sensor for sc200 controller, 0–20 mg/L, <0.1 mg/L error. No membrane changes, no electroly…

4–20 mA / sc200
analyticalopticalchemicaldissolved-oxygenhach +2 more
Environmental ✓ Official

Solar-aspirated radiation shield housing Pt100 temperature and capacitive RH sensors with 4–20 mA outputs. Forced venti…

4–20 mA
weatheraspiratedhumidity4-20maclimate +2 more
Endress+Hauser · Proline Promass F 300
Flow ✓ Official

Two-wire Coriolis mass flowmeter with ±0.1% mass flow accuracy. HART output, hygienic process connections available. Me…

4–20 mA / HART
hartcoriolismass-flowflow4-20ma +1 more
Emerson (Micro Motion) · ELITE CMF100M
Flow ✓ Official

High-accuracy Coriolis mass flowmeter with ±0.05% mass flow accuracy. Simultaneously measures mass flow, volume flow, d…

4–20 mA / HART / Modbus
hartcoriolismass-flowflowmetermodbus +3 more
Keyence · FD-V20A
Flow ✓ Official

DN20 inline vortex flowmeter for 1–100 L/min water measurement. 4–20 mA and NPN pulse outputs, ±2% accuracy, IP67. Push…

4–20 mA / NPN pulse
inlineflow4-20makeyenceflowmeter +1 more
Ifm Electronic · SM6050
Flow ✓ Official

Calorimetric flow sensor for water and aqueous media, 0–2.5 L/min. IO-Link and 4–20 mA outputs, integrated temperature …

4–20 mA / IO-Link
io-linkcalorimetricflow4-20maflowmeter
Flow ✓ Official

Stainless steel turbine flowmeter covering 0.12–1500 L/min. Dual output: 4–20 mA analogue and pulse/frequency. Suitable…

Pulse / 4–20 mA
liquidturbineflow4-20maflowmeter
Yokogawa · ADMAG AXF
Flow ✓ Official

Dual-frequency excitation magnetic flowmeter with ±0.2% accuracy. HART output, TIIS and ATEX certified. Dual-ADMAG tech…

4–20 mA / HART
hartyokogawaelectromagnetic4-20maflow +2 more
Emerson (Rosemount) · 8700M
Flow ✓ Official

Multi-electrode magnetic flowmeter for conductive liquids. DN10–2400, ±0.2% accuracy, 4–20 mA / HART. Multi-electrode d…

4–20 mA / HART
emersonhartelectromagnetic4-20maflow +2 more
ABB · VortexMaster FSV430
Flow ✓ Official

Vortex flowmeter for steam, liquids, and gases. DN15–300, ±0.75% accuracy, 4–20 mA / HART. Integrated temperature and p…

4–20 mA / HART
hartflow4-20maflowmeter
Flow ✓ Official

Custody-transfer ultrasonic gas flowmeter for natural gas and process gas applications. Multipath design, SIL 2 capable…

Modbus RTU / 4–20 mA
flowgas-flowmodbusultrasonicsick +2 more
Flow ✓ Official

Non-invasive clamp-on transit-time ultrasonic flowmeter for DN15–4000 pipes. ±1.5% accuracy, RS-232 and 4–20 mA outputs…

RS-232 / 4–20 mA
non-invasiveultrasonicflow4-20maclamp-on +1 more
Endress+Hauser · Promag W 400
Flow ✓ Official

Electromagnetic flowmeter optimised for wastewater and utility water. DN50–300, ±0.5% accuracy, HART output, IP67/68. P…

4–20 mA / HART
hartelectromagnetic4-20maflowmag-flow +1 more
KROHNE · OPTIFLUX 2000
Flow ✓ Official

Electromagnetic flowmeter for conductive liquids (≥5 µS/cm). DN10–3000 range, ±0.5% accuracy, 4–20 mA / HART / Modbus R…

4–20 mA / HART / Modbus
hartelectromagnetickrohnemag-flowmodbus +3 more
MSA Safety · XCell Pulse
Chemical ✓ Official

Smart catalytic bead (pellistor) combustible gas sensor transmitter with 4–20 mA and Modbus RTU outputs. 0–100% LEL det…

4–20 mA / Modbus RTU
analyticalcombustiblecatalyticrs485chemical +5 more
Honeywell Sensing · 060-0025-03G
Mechanical ✓ Official

Amplified, compensated flush-diaphragm strain gauge transducer with 4–20 mA output. Intended for both liquid/gas pressu…

4–20 mA
strain4-20mamechanicalstructural
Sherborne Sensors · SI-900-0010-2
Position / Motion ✓ Official

Dual-axis inclinometer with 4–20 mA and RS-232 outputs. ±10° range, 0.001° resolution. Force-balance electrolytic sensi…

4–20 mA / RS-232
positionnon-contactdisplacement4-20ma
Meggitt Sensing Systems (Wilcoxon) · 786A-10
Mechanical ✓ Official

Two-wire 4–20 mA vibration transmitter with user-configurable frequency band and full-scale range. Measures velocity RM…

4–20 mA
4-20mamechanicalstructural
Connection Technology Center (CTC) · AC206-1A-1A
Mechanical ✓ Official

Dual-channel 4–20 mA transmitter outputting vibration RMS on channel 1 and temperature on channel 2. Accepts IEPE accel…

4–20 mA
4-20mamechanicalstructural
Hansford Sensors · HS-100A-010
Mechanical ✓ Official

Industrial vibration and temperature transmitter with dual 4–20 mA outputs. First channel: broadband vibration RMS (10–…

4–20 mA
4-20mamechanicalstructural
Amphenol (Wilcoxon Sensing Technologies) · 793L
Mechanical ✓ Official

Loop-powered 4–20 mA vibration transmitter combining an internal IEPE accelerometer with RMS signal processing. Output …

4–20 mA
vibrationaccelerometeriepe4-20mamechanical +1 more
Argus