The open registry for field-deployed sensors & probes
Forge is a community-curated library of sensor and probe definitions — the authoritative source of truth for every device that connects to Vigil. Each definition carries parametric specs, communication protocols, EEPROM descriptors, and physical-quantity mappings that let Argus understand exactly what your sensors are measuring, at what range and resolution. Definitions power automatic unit conversion, anomaly context, and natural-language diagnostics across your whole fleet.
Hydrocarbon and water sensing cable for leak detection under floors and around process equipment. Locates leaks to ±1 m…
Multi-gas ambient air quality transmitter measuring CO, NO2, O3, SO2, PM2.5, temperature, and humidity. Electrochemical…
Combined formaldehyde (HCHO) and environmental sensor module. Electrochemical HCHO measurement 0–1000 ppb with ±15 ppb …
Modbus RTU electrochemical corrosion instrument supporting multiple techniques: LPR, EIS, harmonic distortion analysis.…
Modbus RTU linear polarisation resistance (LPR) corrosion rate transmitter. Electrochemical technique for real-time pit…
Modular multiparameter water quality sonde with 6 sensor ports. Measures pH, conductivity, dissolved oxygen, ORP, turbi…
Deep-sea optical dissolved oxygen optode, 0–500 µmol/L, depth-rated to 6000 m. Luminescent lifetime measurement princip…
Stainless steel 4-electrode conductivity and NTC temperature sensor for CS I/O and SDI-12 data loggers. 0–1000 µS/cm ra…
Luminescent dissolved oxygen sensor for sc200 controller, 0–20 mg/L, <0.1 mg/L error. No membrane changes, no electroly…
Rugged optical dissolved oxygen sensor for continuous water quality monitoring, 0–20 mg/L, SDI-12 and RS-232 outputs. L…
Isolated I²C/UART oxidation-reduction potential circuit, −2000 to +2000 mV, ±1 mV accuracy. Galvanically isolated. Used…
Isolated I²C/UART dissolved oxygen circuit, 0–35 mg/L, ±0.05 mg/L accuracy. Optical luminescent measurement — no membra…
Isolated I²C/UART conductivity circuit with 0.07–500,000 µS/cm auto-range. Computes TDS, salinity, and specific gravity…
Isolated I²C/UART pH measurement circuit, pH 0–14, ±0.001 accuracy. Galvanically isolated to eliminate ground loop erro…
Non-invasive clamp-on transit-time ultrasonic flowmeter for DN15–4000 pipes. ±1.5% accuracy, RS-232 and 4–20 mA outputs…
Electromagnetic flowmeter for conductive liquids (≥5 µS/cm). DN10–3000 range, ±0.5% accuracy, 4–20 mA / HART / Modbus R…
Smart catalytic bead (pellistor) combustible gas sensor transmitter with 4–20 mA and Modbus RTU outputs. 0–100% LEL det…
3-electrode electrochemical CO sensor for safety monitoring applications. 0–500 ppm CO range, ±3% FS accuracy, 300–600 …
Low-cost optical dust density sensor using infrared LED and photodiode. Dual-channel PWM output representing PM2.5 (> 1…
Optical particle sensor using laser scattering and Sensirion SEMS® technology. Measures PM1, PM2.5, PM4, and PM10 mass …
Optical laser particle counter measuring PM1.0, PM2.5, and PM10 mass concentrations. 0–500 µg/m³ range, ±10 µg/m³ accur…
3-electrode electrochemical carbon monoxide sensor. 0–1000 ppm CO range, < 2% FS accuracy, sensitivity 350–550 nA/ppm. …
Miniature photoionization detector (PID) for VOC measurement. 10.6 eV UV lamp ionises organic compounds; 0–6000 ppb iso…
4-electrode electrochemical sensor for hydrogen sulphide detection. 0–100 ppm H₂S, ±3% FS accuracy. Temperature compens…