Forge is a community-curated library of sensor and probe definitions — the authoritative source of truth for every device that connects to Vigil. Each definition carries parametric specs, communication protocols, EEPROM descriptors, and physical-quantity mappings that let Argus understand exactly what your sensors are measuring, at what range and resolution. Definitions power automatic unit conversion, anomaly context, and natural-language diagnostics across your whole fleet.
Low-range differential pressure sensor for medical flow measurement in spirometers and ventilators. 0–125 Pa range, ±0.…
Inline UV transmittance monitor measuring 0–100%UVT at 254 nm for disinfection dose optimization. ±0.5%T accuracy, inte…
Multi-method heat-pulse sap flow sensor measuring whole-tree water consumption. 0.01–1000 g/h range, stem heat balance …
Weather-resistant ultrasonic distance sensor, 0–5 m range, ±1% accuracy. Analog, serial, and PWM outputs. IP67 rated, s…
Two-wire Coriolis mass flowmeter with ±0.1% mass flow accuracy. HART output, hygienic process connections available. Me…
High-accuracy Coriolis mass flowmeter with ±0.05% mass flow accuracy. Simultaneously measures mass flow, volume flow, d…
DN20 inline vortex flowmeter for 1–100 L/min water measurement. 4–20 mA and NPN pulse outputs, ±2% accuracy, IP67. Push…
Calorimetric flow sensor for water and aqueous media, 0–2.5 L/min. IO-Link and 4–20 mA outputs, integrated temperature …
I²C / SPI air velocity sensor module for HVAC duct monitoring. 0–7.2 m/s range, 12-bit resolution. Micro-hotplate MEMS …
I²C mass flow meter for O₂-compatible medical and industrial applications. 0–250 slm, O₂-resistant wetted materials, au…
I²C mass flow meter for air and N₂, 0–200 slm range. CMOSens thermal measurement principle, bidirectional, ±5% FS accur…
Stainless steel turbine flowmeter covering 0.12–1500 L/min. Dual output: 4–20 mA analogue and pulse/frequency. Suitable…
Dual-frequency excitation magnetic flowmeter with ±0.2% accuracy. HART output, TIIS and ATEX certified. Dual-ADMAG tech…
Multi-electrode magnetic flowmeter for conductive liquids. DN10–2400, ±0.2% accuracy, 4–20 mA / HART. Multi-electrode d…
Vortex flowmeter for steam, liquids, and gases. DN15–300, ±0.75% accuracy, 4–20 mA / HART. Integrated temperature and p…
Custody-transfer ultrasonic gas flowmeter for natural gas and process gas applications. Multipath design, SIL 2 capable…
Non-invasive clamp-on transit-time ultrasonic flowmeter for DN15–4000 pipes. ±1.5% accuracy, RS-232 and 4–20 mA outputs…
Electromagnetic flowmeter optimised for wastewater and utility water. DN50–300, ±0.5% accuracy, HART output, IP67/68. P…
Electromagnetic flowmeter for conductive liquids (≥5 µS/cm). DN10–3000 range, ±0.5% accuracy, 4–20 mA / HART / Modbus R…
CMOSens® differential pressure sensor for HVAC duct airflow measurement. ±500 Pa range, ±3% accuracy, 16-bit I²C output…
Capacitive humidity and temperature probe with a single-wire serial output. ±2% RH, ±0.5 °C accuracy. 16-bit resolution…