Forge
Continuis Labs · Sensor Forge

The open registry for field-deployed sensors & probes

Forge is a community-curated library of sensor and probe definitions — the authoritative source of truth for every device that connects to Vigil. Each definition carries parametric specs, communication protocols, EEPROM descriptors, and physical-quantity mappings that let Argus understand exactly what your sensors are measuring, at what range and resolution. Definitions power automatic unit conversion, anomaly context, and natural-language diagnostics across your whole fleet.

Star definitions your deployments depend on
Fork & customise for proprietary hardware variants
Flash EEPROM descriptors directly to probes via PDP
307
Definitions
Submit Sensor
1–24 of 24 sensors matching "optical"
FBGS International · DTG-LBL-1550
Optical ✓ Official

Draw tower grating FBG sensor element with 250 µm cladding diameter and >1M load cycle fatigue life. Interrogator-depen…

Interrogator-dependent
fbgdraw-towerfbgsaerospacecomposite +2 more
Hach · Nitratax sc plus
Chemical ✓ Official

UV-254 dual-beam optical nitrate sensor with automatic wiper for inline wastewater monitoring. 0–50 mg/L NO₃-N range, ±…

Modbus RTU / sc200
nitrateuv254rs485hachwater-treatment +1 more
Vaisala · GMP343
Environmental ✓ Official

CARBOCAP optical CO₂ probe for growth chamber and greenhouse monitoring. 0–5000 ppm range, ±(3 ppm + 1% of reading) acc…

RS-485 / SDI-12
co2opticalrs485vaisalagreenhouse +2 more
Optical ✓ Official

Optical infrared people counter with directional detection (in/out). 4-wire NPN output, 2 m detection range, ±8° narrow…

Digital I/O
occupancypeople-counteropticaldirectionalomron +1 more
Gems Sensors · LS-7
Optical ✓ Official

Miniature optical liquid level switch with no moving parts. Detects presence or absence of liquid via total internal re…

Digital (NPN)
water-leakopticallevel-switchno-moving-partsminiature
Environmental ✓ Official

Multi-gas ambient air quality transmitter measuring CO, NO2, O3, SO2, PM2.5, temperature, and humidity. Electrochemical…

Modbus RTU
iaqambient-airmodbusrs-485no2 +3 more
Environmental ✓ Official

Laser optical PM sensor measuring PM1.0, PM2.5, and PM10 mass concentration, plus particle count by size (0.3–10 µm). U…

UART
iaqpm2.5particulateuartlaser +1 more
Monarch Instrument · ROS-W
Position / Motion ✓ Official

Non-contact reflective optical tachometer for remote speed measurement. 1–99,999 RPM range, RS-232/RS-485 serial output…

RS-485
tachometeropticalnon-contactrs-485rpm
Optical ✓ Official

Compact M12-rated diffuse photoelectric sensor with 100 mm sensing range and background suppression. NPN output, IP67, …

Digital I/O
photoelectricopticalpresence-detectionomron
Banner Engineering · QS18VP6D
Optical ✓ Official

Miniature diffuse-mode photoelectric sensor with background suppression, 10–300 mm sensing range. PNP/NPN output, IP67,…

Digital I/O
photoelectricopticalpresence-detectiondigital-io
Garmin · LIDAR-Lite v3
Position / Motion ✓ Official

Compact laser rangefinder, 0–40 m range, ±2.5 cm accuracy. I²C and PWM outputs, 50 Hz update rate. Low-cost lidar for U…

I²C / PWM
lidarlaseri2cdistancenon-contact
SICK · DT20-P2213
Position / Motion ✓ Official

IO-Link distance sensor with 0.1–3 m range, ±2 mm accuracy. Time-of-flight measurement, background suppression, teach-i…

IO-Link
io-linktime-of-flightdistanceleveloptical
Position / Motion ✓ Official

Laser displacement sensor with 600 mm measurement range and ±0.1% F.S. accuracy. RS-422 output, 1 kHz sampling. Used fo…

RS-422
laseropticalrs-422displacementnon-contact
Aanderaa Data Instruments · 4835
Chemical ✓ Official

Deep-sea optical dissolved oxygen optode, 0–500 µmol/L, depth-rated to 6000 m. Luminescent lifetime measurement princip…

RS-232 / 4–20 mA
deep-seaanalyticalopticalchemicaldissolved-oxygen +2 more
Turner Designs · Cyclops-7F
Optical ✓ Official

Submersible single-channel fluorometer for chlorophyll, turbidity, CDOM, rhodamine, or crude oil detection. 0–5 V outpu…

Analog (0–5 V)
turbiditysubmersibleopticalchlorophyllnon-contact +2 more
Chemical ✓ Official

Luminescent dissolved oxygen sensor for sc200 controller, 0–20 mg/L, <0.1 mg/L error. No membrane changes, no electroly…

4–20 mA / sc200
analyticalopticalchemicaldissolved-oxygenhach +2 more
Chemical ✓ Official

Rugged optical dissolved oxygen sensor for continuous water quality monitoring, 0–20 mg/L, SDI-12 and RS-232 outputs. L…

RS-232 / SDI-12
analyticalopticalchemicaldissolved-oxygenin-situ +2 more
Atlas Scientific · EZO-DO
Chemical ✓ Official

Isolated I²C/UART dissolved oxygen circuit, 0–35 mg/L, ±0.05 mg/L accuracy. Optical luminescent measurement — no membra…

I²C / UART
i2canalyticalopticalchemicaldissolved-oxygen +2 more
Renishaw · RESOLUTE RESA20USB
Optical ✓ Official

Absolute optical linear/rotary encoder with 1 nm resolution and 100 m/s maximum speed. BiSS-C and SSI interfaces, steel…

BiSS-C / SSI
ssiopticalabsolutenon-contactlaser +2 more
Micro-Epsilon · optoNCDT 1302-100
Optical ✓ Official

Laser triangulation displacement sensor with 100 mm measuring range and 0.4 µm resolution. 2 kHz sampling, RS-422 and a…

RS-422 / Analog
opticalnon-contacttriangulationlaserdisplacement
SHINYEI Technology · SM-PWM-01C
Chemical ✓ Official

Low-cost optical dust density sensor using infrared LED and photodiode. Dual-channel PWM output representing PM2.5 (> 1…

PWM (dual channel)
analyticaldustpm2.5chemicalpwm +2 more
Sensirion · SPS30
Chemical ✓ Official

Optical particle sensor using laser scattering and Sensirion SEMS® technology. Measures PM1, PM2.5, PM4, and PM10 mass …

I²C / UART
i2canalyticaldustpm2.5particulate +4 more
Plantower · PMS5003
Chemical ✓ Official

Optical laser particle counter measuring PM1.0, PM2.5, and PM10 mass concentrations. 0–500 µg/m³ range, ±10 µg/m³ accur…

UART
analyticaldustpm2.5particulateuart +3 more
Melexis · MLX90614ESF-AAA
Optical ✓ Official

Factory-calibrated infrared thermometer in TO-39 metal can package. Measures object and ambient temperature via I²C or …

I²C (SMBus) / PWM
i2copticalinfrarednon-contactlaser +1 more