Forge / Honeywell (City Technology) 4CF2 Electrochemical CO Sensor
Honeywell (City Technology) 4CF2 Electrochemical CO Sensor
Honeywell Analytics (City Technology) · 4CF2
Chemical Analog (µA current) Analog ✓ Official

3-electrode electrochemical CO sensor for safety monitoring applications. 0–500 ppm CO range, ±3% FS accuracy, 300–600 nA/ppm sensitivity. Compact 20 mm body with industry-standard 3-pin layout. Extended-life version (CF suffix): ≥ 3 years operational life. For commercial CO alarms, parking garage ventilation, and confined space monitors.

Specifications
Accuracy (% FS) 3.0 % FS
Detection Range (ppm) 0.0–500.0 ppm
Expected Lifetime (years) 3.0 years
Response Time (T90) (s) 30.0 s
Sensitivity (nA/ppm) 300.0–600.0 nA/ppm
Target Gas Carbon monoxide (CO)
Temperature Range (°C) -40.0–50.0 °C