Forge is a community-curated library of sensor and probe definitions — the authoritative source of truth for every device that connects to Vigil. Each definition carries parametric specs, communication protocols, EEPROM descriptors, and physical-quantity mappings that let Argus understand exactly what your sensors are measuring, at what range and resolution. Definitions power automatic unit conversion, anomaly context, and natural-language diagnostics across your whole fleet.
High-accuracy Coriolis mass flowmeter with ±0.05% mass flow accuracy. Simultaneously measures mass flow, volume flow, d…
Calorimetric flow sensor for water and aqueous media, 0–2.5 L/min. IO-Link and 4–20 mA outputs, integrated temperature …
I²C / SPI air velocity sensor module for HVAC duct monitoring. 0–7.2 m/s range, 12-bit resolution. Micro-hotplate MEMS …
I²C mass flow meter for O₂-compatible medical and industrial applications. 0–250 slm, O₂-resistant wetted materials, au…
Dual-frequency excitation magnetic flowmeter with ±0.2% accuracy. HART output, TIIS and ATEX certified. Dual-ADMAG tech…
Multi-electrode magnetic flowmeter for conductive liquids. DN10–2400, ±0.2% accuracy, 4–20 mA / HART. Multi-electrode d…
Custody-transfer ultrasonic gas flowmeter for natural gas and process gas applications. Multipath design, SIL 2 capable…
Non-invasive clamp-on transit-time ultrasonic flowmeter for DN15–4000 pipes. ±1.5% accuracy, RS-232 and 4–20 mA outputs…
Electromagnetic flowmeter optimised for wastewater and utility water. DN50–300, ±0.5% accuracy, HART output, IP67/68. P…
Electromagnetic flowmeter for conductive liquids (≥5 µS/cm). DN10–3000 range, ±0.5% accuracy, 4–20 mA / HART / Modbus R…
Industrial acoustic emission piezoelectric transducer covering 50–400 kHz with integral cable. Rated −55 to 120°C, IP67…
1 MHz piezoelectric contact/immersion ultrasonic transducer for NDE and AE applications. 13 mm element diameter, IEPE-c…
High-sensitivity wideband acoustic emission sensor covering 100–900 kHz. Optional integrated preamplifier. 0 dBV refere…
Miniature 300 kHz acoustic emission sensor for tight-space installations. Broadband 100–400 kHz response, piezoceramic …
150 kHz resonant acoustic emission transducer for structural monitoring, leak detection, and corrosion AE testing. 25–7…
Smart catalytic bead (pellistor) combustible gas sensor transmitter with 4–20 mA and Modbus RTU outputs. 0–100% LEL det…
3-electrode electrochemical CO sensor for safety monitoring applications. 0–500 ppm CO range, ±3% FS accuracy, 300–600 …
Low-cost optical dust density sensor using infrared LED and photodiode. Dual-channel PWM output representing PM2.5 (> 1…
Optical particle sensor using laser scattering and Sensirion SEMS® technology. Measures PM1, PM2.5, PM4, and PM10 mass …
Optical laser particle counter measuring PM1.0, PM2.5, and PM10 mass concentrations. 0–500 µg/m³ range, ±10 µg/m³ accur…
3-electrode electrochemical carbon monoxide sensor. 0–1000 ppm CO range, < 2% FS accuracy, sensitivity 350–550 nA/ppm. …
Miniature photoionization detector (PID) for VOC measurement. 10.6 eV UV lamp ionises organic compounds; 0–6000 ppb iso…
4-electrode electrochemical sensor for hydrogen sulphide detection. 0–100 ppm H₂S, ±3% FS accuracy. Temperature compens…
Galvanic cell oxygen sensor for ambient O₂ monitoring (0–25% v/v). Flat-cap design for diffusion control. Output 13–17 …