Forge
Continuis Labs · Sensor Forge

The open registry for field-deployed sensors & probes

Forge is a community-curated library of sensor and probe definitions — the authoritative source of truth for every device that connects to Vigil. Each definition carries parametric specs, communication protocols, EEPROM descriptors, and physical-quantity mappings that let Argus understand exactly what your sensors are measuring, at what range and resolution. Definitions power automatic unit conversion, anomaly context, and natural-language diagnostics across your whole fleet.

Star definitions your deployments depend on
Fork & customise for proprietary hardware variants
Flash EEPROM descriptors directly to probes via PDP
307
Definitions
Submit Sensor
121–144 of 215 sensors matching "ati"  · Page 6 of 9
Gill Instruments · MaxiMet GMX501
Environmental ✓ Official

All-in-one ultrasonic weather station measuring wind speed/direction, barometric pressure, temperature, and RH. RS-232/…

RS-232 / RS-485
rs485all-in-oneultrasonicwindweather +2 more
Kaman Precision · SMU-9700
Position / Motion ✓ Official

Non-contact eddy current displacement sensor for conductive metal targets. 0.01–3 mm range, 100 kHz bandwidth, ±10 V an…

Analog (±10 V)
positioneddy-currentnon-contactdisplacement
Micro-Epsilon · optoNCDT 1302-100
Optical ✓ Official

Laser triangulation displacement sensor with 100 mm measuring range and 0.4 µm resolution. 2 kHz sampling, RS-422 and a…

RS-422 / Analog
opticalnon-contacttriangulationlaserdisplacement
MTS Sensors · RHM0550MD701A01
Position / Motion ✓ Official

550 mm stroke magnetostrictive linear position sensor with SSI 25-bit output, ±50 µm accuracy, IP67. High repeatability…

SSI / Analog
positionssimagnetostrictivenon-contactlinear +1 more
Balluff · BTL7-A501-M0100-B-S32
Position / Motion ✓ Official

Non-contact magnetostrictive linear position sensor, 100 mm stroke, ±20 µm accuracy. SSI and Profibus outputs. Suitable…

SSI / Profibus
positionssimagnetostrictivenon-contactlinear +1 more
Keyence · FD-V20A
Flow ✓ Official

DN20 inline vortex flowmeter for 1–100 L/min water measurement. 4–20 mA and NPN pulse outputs, ±2% accuracy, IP67. Push…

4–20 mA / NPN pulse
inlineflow4-20makeyenceflowmeter +1 more
TE Connectivity · FS3000-1005
Flow ✓ Official

I²C / SPI air velocity sensor module for HVAC duct monitoring. 0–7.2 m/s range, 12-bit resolution. Micro-hotplate MEMS …

I²C / SPI
i2cspiflowhvacair-velocity +1 more
Sensirion · SFM3300-AW
Flow ✓ Official

I²C mass flow meter for O₂-compatible medical and industrial applications. 0–250 slm, O₂-resistant wetted materials, au…

I²C
i2csensirionmass-flowflowflowmeter +1 more
Sensirion · SFM3000-200-C
Flow ✓ Official

I²C mass flow meter for air and N₂, 0–200 slm range. CMOSens thermal measurement principle, bidirectional, ±5% FS accur…

I²C
i2csensirionmass-flowflowflowmeter
Yokogawa · ADMAG AXF
Flow ✓ Official

Dual-frequency excitation magnetic flowmeter with ±0.2% accuracy. HART output, TIIS and ATEX certified. Dual-ADMAG tech…

4–20 mA / HART
hartyokogawaelectromagnetic4-20maflow +2 more
ABB · VortexMaster FSV430
Flow ✓ Official

Vortex flowmeter for steam, liquids, and gases. DN15–300, ±0.75% accuracy, 4–20 mA / HART. Integrated temperature and p…

4–20 mA / HART
hartflow4-20maflowmeter
Flow ✓ Official

Custody-transfer ultrasonic gas flowmeter for natural gas and process gas applications. Multipath design, SIL 2 capable…

Modbus RTU / 4–20 mA
flowgas-flowmodbusultrasonicsick +2 more
KROHNE · OPTIFLUX 2000
Flow ✓ Official

Electromagnetic flowmeter for conductive liquids (≥5 µS/cm). DN10–3000 range, ±0.5% accuracy, 4–20 mA / HART / Modbus R…

4–20 mA / HART / Modbus
hartelectromagnetickrohnemag-flowmodbus +3 more
Olympus (Evident) · V103-RM
Mechanical ✓ Official

1 MHz piezoelectric contact/immersion ultrasonic transducer for NDE and AE applications. 13 mm element diameter, IEPE-c…

IEPE / charge
iepeultrasonicstructuralmechanicalpiezoelectric +1 more
Vallen Systeme · VS375-M
Mechanical ✓ Official

High-sensitivity wideband acoustic emission sensor covering 100–900 kHz. Optional integrated preamplifier. 0 dBV refere…

Wideband voltage
widebandacoustic-emissionstructuralmechanicalndt
MISTRAS Group (PAC) · Nano30
Mechanical ✓ Official

Miniature 300 kHz acoustic emission sensor for tight-space installations. Broadband 100–400 kHz response, piezoceramic …

Wideband voltage
acoustic-emissionminiaturemechanicalpiezoelectricstructural
MISTRAS Group (PAC) · R15α
Mechanical ✓ Official

150 kHz resonant acoustic emission transducer for structural monitoring, leak detection, and corrosion AE testing. 25–7…

Wideband voltage
acoustic-emissionstructuralmechanicalpiezoelectricndt
Honeywell Analytics (City Technology) · 4CF2
Chemical ✓ Official

3-electrode electrochemical CO sensor for safety monitoring applications. 0–500 ppm CO range, ±3% FS accuracy, 300–600 …

Analog (µA current)
coanalyticalchemicalgaswater-quality +2 more
SHINYEI Technology · SM-PWM-01C
Chemical ✓ Official

Low-cost optical dust density sensor using infrared LED and photodiode. Dual-channel PWM output representing PM2.5 (> 1…

PWM (dual channel)
analyticaldustpm2.5chemicalpwm +2 more
Sensirion · SPS30
Chemical ✓ Official

Optical particle sensor using laser scattering and Sensirion SEMS® technology. Measures PM1, PM2.5, PM4, and PM10 mass …

I²C / UART
i2canalyticaldustpm2.5particulate +4 more
Plantower · PMS5003
Chemical ✓ Official

Optical laser particle counter measuring PM1.0, PM2.5, and PM10 mass concentrations. 0–500 µg/m³ range, ±10 µg/m³ accur…

UART
analyticaldustpm2.5particulateuart +3 more
Chemical ✓ Official

3-electrode electrochemical carbon monoxide sensor. 0–1000 ppm CO range, < 2% FS accuracy, sensitivity 350–550 nA/ppm. …

Analog (µA current)
coanalyticalchemicalgaswater-quality +2 more
Chemical ✓ Official

Miniature photoionization detector (PID) for VOC measurement. 10.6 eV UV lamp ionises organic compounds; 0–6000 ppb iso…

Analog (µA current)
analyticalvocphotoionizationpidanalog +3 more
Chemical ✓ Official

4-electrode electrochemical sensor for nitrogen dioxide. 0–20 ppm NO₂ detection, ±0.5 ppm accuracy below 2 ppm. High se…

Analog (µA current)
analyticalchemicalgasno2water-quality +2 more
Argus
Operational insights · Institutional memory
Argus is thinking…