The open registry for field-deployed sensors & probes
Forge is a community-curated library of sensor and probe definitions — the authoritative source of truth for every device that connects to Vigil. Each definition carries parametric specs, communication protocols, EEPROM descriptors, and physical-quantity mappings that let Argus understand exactly what your sensors are measuring, at what range and resolution. Definitions power automatic unit conversion, anomaly context, and natural-language diagnostics across your whole fleet.
Precision I²C ambient light sensor matching the human eye's spectral response. 0.01–83,000 lux range with 12-bit result…
Enterprise refrigeration controller and monitoring node with Modbus RTU, LonWorks, and BACnet support. 16 analog/digita…
Commercial refrigerant gas monitor with Modbus RTU RS-485 interface for BMS integration. Detects HFCs, HCFCs, and HFO r…
Fixed-mount refrigerant gas detector supporting 50+ refrigerant types including R-22, R-134a, R-410A, R-1234yf, and nat…
Commercial-grade passive infrared presence detector with KNX and Modbus RTU output. 360° detection, 8 m radius, integra…
Ultra-wideband (UWB) radar module for through-wall presence and respiration detection. UART interface, 0–5 m range, 3.3…
Dual-element passive infrared (PIR) motion detector for human presence sensing. 100° detection angle, 10 m range, 8–14 …
8×8 pixel far-infrared thermopile array for occupancy and thermal presence detection. I²C interface at up to 10 Hz fram…
Compact I²C metal oxide IAQ sensor reporting equivalent CO2 (450–2000 ppm) and TVOC index. Calibrated IAQ output requir…
Digital multi-gas metal oxide sensor with 3 independent hot-plates for TVOC (0–65000 ppb) and eCO2 (400–65000 ppm). I²C…
All-in-one IAQ sensor module measuring PM1/2.5/4/10, VOC index, NOx index, humidity, and temperature. UART and I²C inte…
I²C / SPI air velocity sensor module for HVAC duct monitoring. 0–7.2 m/s range, 12-bit resolution. Micro-hotplate MEMS …
Dual-channel MOX gas sensor measuring both VOC and NOx indices on separate sensing elements. VOC Index 0–500; NOx Index…
Industrial-grade NDIR CO₂ sensor with Modbus RTU / I²C / UART interfaces. 0–2% (20,000 ppm) range with ±30 ppm accuracy…
Miniature photoacoustic NDIR CO₂ sensor with integrated humidity and temperature measurement. 400–2000 ppm CO₂ range, ±…
Amplified, compensated, and calibrated MEMS pressure sensor with SPI digital output. 0–15 psi absolute, ±0.25% FSS tota…
Variable-capacitance differential pressure transducer for HVAC, cleanrooms, and laboratory fume hoods. ±0.25% FS accura…
CMOSens® differential pressure sensor for HVAC duct airflow measurement. ±500 Pa range, ±3% accuracy, 16-bit I²C output…
Compensated and calibrated digital gauge pressure sensor, 0–15 psi range. 24-bit output over I²C with ±0.25% FSS accura…
Premium digital humidity and temperature sensor with ±1.5% RH accuracy and integrated PTFE filter. I²C output, 14-bit r…
Flat-format humidity and temperature sensor with ±1.5% RH and ±0.1 °C accuracy. Designed for demanding HVAC, laboratory…
High-accuracy, low-power digital temperature sensor in 3 × 3 mm DFN package. ±0.1 °C accuracy across −10 to 85 °C, 14-b…