Forge
Continuis Labs · Sensor Forge

The open registry for field-deployed sensors & probes

Forge is a community-curated library of sensor and probe definitions — the authoritative source of truth for every device that connects to Vigil. Each definition carries parametric specs, communication protocols, EEPROM descriptors, and physical-quantity mappings that let Argus understand exactly what your sensors are measuring, at what range and resolution. Definitions power automatic unit conversion, anomaly context, and natural-language diagnostics across your whole fleet.

Star definitions your deployments depend on
Fork & customise for proprietary hardware variants
Flash EEPROM descriptors directly to probes via PDP
307
Definitions
Submit Sensor
25–48 of 58 sensors matching "analog"  · Page 2 of 3
3M · 3M VHB Indicator
Mechanical ✓ Official

Simple analog vibration indicator using piezoelectric element. Sticks to surfaces, outputs analog voltage proportional …

Analog
vibrationanalogpiezoelectricmachine-healthlow-cost
Hukseflux · SR05
Optical ✓ Official

ISO 9060 first class pyranometer for global and diffuse solar irradiance, 285–3000 nm. Sensitivity 7–14 µV/(W/m²), <4% …

Analog
pyranometersolar-radiationanalogirradiancepv-monitoring
Kipp & Zonen · CMP3
Optical ✓ Official

ISO 9060 secondary standard pyranometer measuring global solar irradiance 285–2800 nm. Sensitivity 5–15 µV/(W/m²), anal…

Analog
pyranometersolar-radiationanalogirradiancemeteorology
Analog Devices · ADXL355BEZ
Mechanical ✓ Official

3-axis SPI/I²C MEMS accelerometer with ultra-low noise and drift. ±2/±4/±8 g ranges, 20-bit ADC, built-in temperature s…

SPI / I²C
memsaccelerometerspii2cseismic +1 more
Mechanical ✓ Official

10 Hz three-component geophone (3C) with 28 V/(m/s) sensitivity per axis, cross-axis rejection >40 dB. Used in reflecti…

Analog
geophoneseismic3-componentanalogborehole
Geospace Technologies · GS-11D
Mechanical ✓ Official

Industry-standard 4.5 Hz vertical geophone element. Moving-coil velocity transducer, 28 Ω coil resistance. Used in seis…

Analog
geophoneseismicanalogvelocityground-motion
Allegro MicroSystems · ACS712ELCTR-30A-T
Electrical ✓ Official

Fully integrated Hall-effect linear current sensor IC, ±30 A range, 2.5 V offset analog output. 66 mV/A sensitivity, DC…

Analog
hall-effectcurrentanalogicmotor-drive
Electrical ✓ Official

Split-core current transformer for non-invasive AC current measurement, 0–100 A range. Analog voltage output (0–1 V). C…

Analog
current-transformerctanalogac-currentenergy-monitoring
Micro-Epsilon · optoNCDT 1302-20
Position / Motion ✓ Official

Compact laser triangulation displacement sensor, 20 mm measurement range, ±0.1% F.S. linearity. RS-422 and analog outpu…

RS-422 / Analog
lasertriangulationrs-422displacementnon-contact
Environmental ✓ Official

Weather-resistant ultrasonic distance sensor, 0–5 m range, ±1% accuracy. Analog, serial, and PWM outputs. IP67 rated, s…

Analog / Serial
ultrasoniclevelanalogip67tank-level
R.M. Young · 27106T
Environmental ✓ Official

360° stainless steel wind vane with ratiometric 0.5–4.5 V output. 0.3 m/s starting threshold, suitable for harsh enviro…

Analog (0.5–4.5 V)
weatheranalogwinddirectionclimate +1 more
R.M. Young · 05103
Environmental ✓ Official

Classic 4-blade propeller/vane wind monitor for 0–100 m/s wind speed and 360° direction. AC output proportional to wind…

Pulse + Analog
environmentalanalogwindweatherclimate +1 more
TE Connectivity · DC-750
Position / Motion ✓ Official

DC-in/DC-out LVDT linear variable differential transformer with ±19 mm range and 0.1% linearity. Temperature-compensate…

Analog (DC/DC)
positionnon-contactanaloglineardisplacement +1 more
Micro-Epsilon · capaNCDT 6200
Position / Motion ✓ Official

Ultra-high-resolution capacitive displacement sensor with 2 mm range and 0.1 nm resolution. Analogue and EtherCAT outpu…

Analog / EtherCAT
positionprecisionnon-contactcapacitivedisplacement
Kaman Precision · SMU-9700
Position / Motion ✓ Official

Non-contact eddy current displacement sensor for conductive metal targets. 0.01–3 mm range, 100 kHz bandwidth, ±10 V an…

Analog (±10 V)
positioneddy-currentnon-contactdisplacement
Novotechnik · T060-0-A-10
Position / Motion ✓ Official

60 mm stroke conductive-plastic potentiometric linear position transducer, 10 kΩ, 0–10 V output, ±0.1% linearity. Rated…

Analog (0–10 V)
positionnon-contactpotentiometriclineardisplacement +1 more
Micro-Epsilon · optoNCDT 1302-100
Optical ✓ Official

Laser triangulation displacement sensor with 100 mm measuring range and 0.4 µm resolution. 2 kHz sampling, RS-422 and a…

RS-422 / Analog
opticalnon-contacttriangulationlaserdisplacement
Flow ✓ Official

Stainless steel turbine flowmeter covering 0.12–1500 L/min. Dual output: 4–20 mA analogue and pulse/frequency. Suitable…

Pulse / 4–20 mA
liquidturbineflow4-20maflowmeter
Chemical ✓ Official

3-electrode electrochemical carbon monoxide sensor. 0–1000 ppm CO range, < 2% FS accuracy, sensitivity 350–550 nA/ppm. …

Analog (µA current)
coanalyticalchemicalgaswater-quality +2 more
Chemical ✓ Official

Miniature photoionization detector (PID) for VOC measurement. 10.6 eV UV lamp ionises organic compounds; 0–6000 ppb iso…

Analog (µA current)
analyticalvocphotoionizationpidanalog +3 more
Chemical ✓ Official

4-electrode electrochemical sensor for hydrogen sulphide detection. 0–100 ppm H₂S, ±3% FS accuracy. Temperature compens…

Analog (µA current)
analyticalchemicalh2sgaswater-quality +2 more
Chemical ✓ Official

Galvanic cell oxygen sensor for ambient O₂ monitoring (0–25% v/v). Flat-cap design for diffusion control. Output 13–17 …

Analog (µA current)
oxygenanalyticalo2analogelectrochemical +3 more
Chemical ✓ Official

4-electrode electrochemical sensor for nitrogen dioxide. 0–20 ppm NO₂ detection, ±0.5 ppm accuracy below 2 ppm. High se…

Analog (µA current)
analyticalchemicalgasno2water-quality +2 more
Chemical ✓ Official

4-electrode amperometric electrochemical sensor for carbon monoxide detection. 0–1000 ppm CO range, ±2% FS accuracy. Au…

Analog (µA current)
coanalyticalchemicalgaswater-quality +2 more
Argus
Operational insights · Institutional memory