Forge
Continuis Labs · Sensor Forge

The open registry for field-deployed sensors & probes

Forge is a community-curated library of sensor and probe definitions — the authoritative source of truth for every device that connects to Vigil. Each definition carries parametric specs, communication protocols, EEPROM descriptors, and physical-quantity mappings that let Argus understand exactly what your sensors are measuring, at what range and resolution. Definitions power automatic unit conversion, anomaly context, and natural-language diagnostics across your whole fleet.

Star definitions your deployments depend on
Fork & customise for proprietary hardware variants
Flash EEPROM descriptors directly to probes via PDP
307
Definitions
Submit Sensor
1–8 of 8 sensors
Texas Instruments · AFE4400
Other ✓ Official

Integrated analog front end for SpO2 pulse oximetry with LED driver, transimpedance amplifier, and ADC. SPI interface, …

SPI
spo2pulse-oximeterafetispi +3 more
Maxim (Analog Devices) · MAX30205
Other ✓ Official

I²C clinical body temperature sensor with ±0.1°C accuracy over 37–39°C body temp range. 0–50°C total range, 16-bit reso…

I²C
body-temperatureclinicalthermometermaximwearable +2 more
Other ✓ Official

Low-range differential pressure sensor for medical flow measurement in spirometers and ventilators. 0–125 Pa range, ±0.…

Analog
differential-pressurespirometerventilatorhoneywellanalog +2 more
Other ✓ Official

Sidestream ETCO2 capnography module for intubated and non-intubated patient monitoring. 0–150 mmHg range, ±2 mmHg accur…

RS-232
capnographyetco2co2respiratorymasimo +3 more
Nonin Medical · OEM III
Other ✓ Official

FDA-cleared OEM SpO2 module for integration into clinical monitors and hospital equipment. 70–100% SpO2 ±2% accuracy, m…

RS-232 / UART
spo2pulse-oximeterfdaclinicalnonin +3 more
Other ✓ Official

8-channel simultaneous 24-bit biopotential amplifier with 1 µV RMS noise for clinical EEG and EMG. SPI interface, integ…

SPI
eegemgbiopotentialafeti +4 more
Texas Instruments · ADS1293
Other ✓ Official

24-bit 3-channel simultaneous ECG analog front end with 0.4 µV noise floor and 1.8 V supply. SPI interface, integrated …

SPI
ecgbiopotentialafetispi +3 more
Maxim (Analog Devices) · MAX30102
Other ✓ Official

Integrated pulse oximeter and heart rate biosensor with LED driver and photodetector on I²C. Measures SpO2 and heart ra…

I²C
pulse-oximeterspo2heart-ratemaximwearable +2 more
Argus
Operational insights · Institutional memory
Argus is thinking…