Forge / MAX31855 K-Type Thermocouple Amplifier
MAX31855 K-Type Thermocouple Amplifier
Analog Devices (Maxim) · MAX31855KASA+
Environmental SPI (read-only) GPIO ✓ Official

SPI thermocouple-to-digital converter with built-in 14-bit ADC and cold-junction compensation. Supports Type K thermocouple from −200 to +1350 °C with ±2 °C thermocouple accuracy and ±0.063 °C internal temperature resolution. Detects open-circuit, short-to-VCC, and short-to-GND faults.

Specifications
Data Width (bits) 32.0 bits
Fault Detection Open, short-to-VCC, short-to-GND
Internal Temp Range (°C) -40.0–125.0 °C
Internal Temp Resolution (°C/LSB) 0.0625 °C/LSB
Supply Voltage (V) 3.0–3.6 V
TC Accuracy (°C) 2.0 °C
TC Resolution (°C/LSB) 0.25 °C/LSB
TC Temperature Range (°C) -200.0–1350.0 °C